Super-micro-computer AOC-USAS-L4i Manual de usuario Pagina 49

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 48
6-1
Safety Information and Technical Specifications
Chapter 6
Configuration
You use MegaRAID Storage Manager software to create and modify storage
configurations. RAID 0, RAID 1, RAID 5, and RAID 10 storage configurations are
supported.
Important: LSI recommends that you do not use both SAS and SATA drives in
the same array. Using different drive interfaces in this way could cause unpredict
-
able behavior, decreased performance, an increased error count, and decreased
MTBF.
Note: You cannot create or modify a storage configuration unless you are logged
on with administrator privileges.
6-1 Creating a New Storage Configuration
You can use the MegaRAID Storage Manager Configuration Wizard to create new
storage configurations. To open the MegaRAID Storage Manager Configuration
Wizard, select a controller in the left panel of the MegaRAID Storage Manager
window and then select Operations -> Advanced Operations -> Configuration ->
Configuration Wizard.
Vista de pagina 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 65 66

Comentarios a estos manuales

Sin comentarios