Super-micro-computer 5014C-MF Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Super-micro-computer 5014C-MF. SUPER MICRO Computer 5014C-MF User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 112
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - SUPER

SUPERSUPERSERVER 5014C-MF USER’S MANUAL Revision 1.0a®

Pagina 2

xNotesSUPERSERVER 5014C-MF User's Manual

Pagina 3 - Manual Organization

C-6SUPERSERVER 5014C-MF User's Manual7. When the pop-up submenu, indicating "SPAN-1" appears as shown above, use the space bar to confi

Pagina 4

Appendix C: Software InstallationC-78. When the screen shown above appears, highlight RAID 1 to select it (this is the default setting), or press <

Pagina 5

C-8SUPERSERVER 5014C-MF User's ManualInitializing Disk DrivesIf an installed disk does not appear in the disk selection list for creating a new a

Pagina 6 - Table of Contents

Appendix C: Software InstallationC-94. After selecting the Logical Drive, press <F10> to initialize the selected disk drive.5. When prompted for

Pagina 7 - Chapter 4: System Safety

C-10SUPERSERVER 5014C-MF User's Manual3. Use the space bar to select the physical drive you wish to confi gure as a Hot Spare drive from the pop-u

Pagina 8 - Chapter 7: BIOS

Appendix C: Software InstallationC-11C-2 Installing WindowsXP/2000/2003 for RAID Systems Note: It is strongly recommended that you initialize the di

Pagina 9 - Appendices:

C-12SUPERSERVER 5014C-MF User's ManualC-3 Installing Other Software Programs and DriversInstalling Other Drivers After you've installed the

Pagina 10

Appendix C: Software InstallationC-13Supero Doctor IIIThe Supero Doctor III program is a web base management tool that supports remote management capa

Pagina 11 - Chapter 1

C-14SUPERSERVER 5014C-MF User's ManualNote: SD III Software Revision 1.0 can be downloaded from our web site at: ftp://ftp.supermicro.com/utility

Pagina 12 - 1-2 Motherboard Features

D-1Appendix D: System Specifi cations Appendix D System Spec

Pagina 13 - Other Features

Chapter 1 Introduction1-1 OverviewThe Supermicro SuperServer 5014C-MF is a high-end single processor, 1U rack-mount server with sta

Pagina 14 - System Block Diagram

D-2SUPERSERVER 5014C-MF User's ManualWeight Gross Weight: 16.5 lbs. (7.5 kg.) System Cooling One (1) 10-cm 5K rpm cooling fan

Pagina 15 - 1-3 Server Chassis Features

D-3Appendix D: System Specifi cationsSafety: EN 60950/IEC 60950-Compliant UL Listed (USA) CUL Listed (Canada) TUV Certifi ed (Ge

Pagina 16 - Cooling System

D-4SUPERSERVER 5014C-MF User's ManualNotes

Pagina 17 - 1-4 Contacting Supermicro

1-2SUPERSERVER 5014C-MF User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 5014C-MF lies the P8SCT, a single processor motherbo

Pagina 18

Chapter 1: Introduction1-3Onboard Controllers/Front Side PortsAn onboard IDE controller supports one fl oppy drive and up to four Ultra ATA 100 hard dr

Pagina 19 - Server Installation

1-4SUPERSERVER 5014C-MF User's ManualFigure 1-1 . Intel E7221 Chipset: System Block Diagram Note: This is a general block diagram. Please see C

Pagina 20 - Warnings and Precautions!

Chapter 1: Introduction1-51-3 Server Chassis FeaturesThe SuperServer 5014C-MF is built on the SC513L-260 1U rackmount server chassis. The SC513L-260

Pagina 21 - Rack Mounting Considerations

1-6SUPERSERVER 5014C-MF User's ManualCooling SystemThe SC513L-260 chassis has an innovative cooling design that features one 10-cm blower-type sy

Pagina 22 - Basic Installation Procedure

Chapter 1: Introduction1-71-4 Contacting SupermicroHeadquarters Address: SuperMicro Computer, Inc. 980 Rock Ave.

Pagina 23 - Installing the Chassis Rails

1-8SUPERSERVER 5014C-MF User's ManualNotes

Pagina 24 - Installing the Rack Rails

Chapter 2: Server Installation2-1Chapter 2 Server Installation 2-1 OverviewThis chapter provides a quick setup checklist to get

Pagina 25

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Pagina 26

2-2SUPERSERVER 5014C-MF User's ManualChoosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front

Pagina 27

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Pagina 28

2-4SUPERSERVER 5014C-MF User's Manual2-4 Installing the System into a RackThis section provides information on installing the SuperServer 5014C-

Pagina 29

Chapter 2: Server Installation2-5Installing the Chassis RailsPosition the fi xed chassis rail sections you just removed along the side of the chassis s

Pagina 30

2-6SUPERSERVER 5014C-MF User's ManualInstalling the Server into the RackYou should now have rails attached to both the chassis and the rack unit.

Pagina 31 - System Interface

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a RackInstalling the Server into a Telco RackIf you are installing the SuperS

Pagina 32 - 3-3 Control Panel LEDs

2-8SUPERSERVER 5014C-MF User's ManualFigure 2-4. Installing the Server into a Telco Rack

Pagina 33 - Chapter 3: System Interface

Chapter 2: Server Installation2-92-5 Checking the Motherboard SetupAfter you install the 5014C-MF in the rack, you will need to open the unit to make

Pagina 34

2-10SUPERSERVER 5014C-MF User's ManualFigure 2-5. Accessing the Inside of the System

Pagina 35 - System Safety

Chapter 2: Server Installation2-112-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the Serial ATA drives

Pagina 36

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It pro-vides information for the installation

Pagina 37 - 4-3 ESD Precautions

2-12SUPERSERVER 5014C-MF User's ManualNotes

Pagina 38 - 4-4 Operating Precautions

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel to keep you constantly informed

Pagina 39 - Advanced Motherboard Setup

3-2SUPERSERVER 5014C-MF User's Manual3-3 Control Panel LEDsThe control panel located on the front of the chassis has fi ve LEDs. These LEDs provi

Pagina 40 - 5-2 Motherboard Installation

Chapter 3: System Interface3-3 Power: Indicates power is being supplied to the system's power supply unit. This LED should normally be illumi

Pagina 41 - 5-3 Connecting Cables

3-4SUPERSERVER 5014C-MF User's ManualNotes

Pagina 42 - 5-4 I/O Ports

Chapter 4: System Safety4-1 Chapter 4 System Safety!Basic electrical safety precautions should be followed to protect yourself from

Pagina 43 - 5-5 Installing the Processor

SUPERSERVER 5014C-MF User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:  Keep the area around the Super

Pagina 44

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Pagina 45 - Heatsink Removal

SUPERSERVER 5014C-MF User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 5014C-MF i

Pagina 46 - 5-6 Installing Memory

Chapter 5: Advanced Motherboard Setup5-1 Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install the P8

Pagina 47 - 5-7 Adding PCI Cards

SUPERSERVER 5014C-MF User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general overview

Pagina 48 - 5-8 Motherboard Details

5-2SUPERSERVER 5014C-MF User's Manual5-2 Motherboard InstallationThis section explains the fi rst step of physically mounting the P8SCT into the S

Pagina 49 - P8SCT Quick Reference

Chapter 5: Advanced Motherboard Setup5-35-3 Connecting CablesNow that the motherboard is installed, the next step is to connect the cables to the boar

Pagina 50 - Defi nitions

5-4SUPERSERVER 5014C-MF User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 belo

Pagina 51 - NIC1 (JLAN1) LED

Chapter 5: Advanced Motherboard Setup5-55-5 Installing the Processor Processor Support The P8SCT has a single LGA775 socket, which su

Pagina 52

5-6SUPERSERVER 5014C-MF User's Manual4. Use your thumb and index fi nger to hold the CPU at the north center and south center edges of the CPU. 5.

Pagina 53 - JLAN1/2 (Ethernet Ports)

Chapter 5: Advanced Motherboard Setup5-7Heatsink Installation1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount ha

Pagina 54

5-8SUPERSERVER 5014C-MF User's Manual5-6 Installing Memory 1. Memory support The P8SCT supports up to 4 GB of dual or single-chann

Pagina 55 - 5-10 Jumper Settings

Chapter 5: Advanced Motherboard Setup5-95-7 Adding PCI Cards1. 64-bit PCI-X slotThe 5014C-MT has a riser card (p/n CSE-RR1U-X) designed specifi cally f

Pagina 56

5-10SUPERSERVER 5014C-MF User's Manual Figure 5-4. P8SCT Layout (not drawn to scale)Note: Jumpers not indicated are for test purposes only.

Pagina 57 - SMBus to PCI

Chapter 5: Advanced Motherboard Setup5-11P8SCT Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear See Section 5-10 JP1/JP2

Pagina 59 - Parallel Port Connector

5-12SUPERSERVER 5014C-MF User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on th

Pagina 60 - Floppy Connector

Chapter 5: Advanced Motherboard Setup5-13Overheat LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warning of c

Pagina 61 - IDE Connector

5-14SUPERSERVER 5014C-MF User's ManualPower On LEDThe Power On LED connector is lo-cated on pins 15 and 16 of JF1 (use JLED for a 3-pin connector

Pagina 62

Chapter 5: Advanced Motherboard Setup5-15Wake-On-LANThe Wake-On-LAN header is des-ignated JWOL on the motherboard. See the table on the right for pin

Pagina 63 - Advanced Chassis Setup

5-16SUPERSERVER 5014C-MF User's ManualPower LED The Power LED header is located on JLED. This header provides LED in-dication of power being sup

Pagina 64 - 6-2 Control Panel

Chapter 5: Advanced Motherboard Setup5-175-10 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers can be us

Pagina 65 - 6-3 System Fan

5-18SUPERSERVER 5014C-MF User's ManualSystem Power Force OnJumper JPF allows you to enable or disable the Force-Power-On function. If enabled, s

Pagina 66 - Serial ATA Drive Installation

Chapter 5: Advanced Motherboard Setup5-19JLAN1/JLAN2 Enable/Disable Change the setting of jumper JPL1 to enable or disable the JLAN1 port and JPL2 to

Pagina 67

5-20SUPERSERVER 5014C-MF User's ManualPCI-X Slot Speed SelectJP3 allows you to select the Frequency for the PCI-X slot. The default setting is C

Pagina 68 - 6-5 Power Supply

Chapter 5: Advanced Motherboard Setup5-215-12 Parallel Port, Floppy and IDE Drive ConnectionsUse the following information to connect the IDE hard di

Pagina 69 - Chapter 7

viTable of ContentsPrefaceAbout This Manual ... ii

Pagina 70 - 7-3 Main BIOS Setup

5-22SUPERSERVER 5014C-MF User's ManualFloppy Drive ConnectorPin Defi nitions (Floppy)Pin# Defi nition Pin # Defi nition1 G

Pagina 71

Chapter 5: Advanced Motherboard Setup5-23IDE ConnectorThere are no jumpers to confi gure the onboard IDE interface "IDE". See the table belo

Pagina 72

5-24SUPERSERVER 5014C-MF User's ManualNotes

Pagina 73 - 7-4 Advanced BIOS Setup

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and p

Pagina 74

6-2SUPERSERVER 5014C-MF User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the chassis) must

Pagina 75

Chapter 6: Advanced Chassis Setup6-36-3 System FanA 10-cm blower fan provides the cooling for the SuperServer 5014C-MF. The chas-sis includes air sea

Pagina 76

6-4SUPERSERVER 5014C-MF User's ManualSerial ATA Drive Installation1. Accessing the inside of the system The Serial ATA drive is installed int

Pagina 77 - PnP/PCI Confi guration

Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Removing/Installing the Hard DriveFigure 6-3. Internal Hard Drive Bay

Pagina 78

6-6SUPERSERVER 5014C-MF User's Manual6-5 Power SupplyThe SuperServer 5014C-MF has a single 260 watt power supply. This power sup-ply has the cap

Pagina 79 - 7-4.5 Hardware Monitors

Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the AwardBIOS for the P8SCT. The Award ROM BIOS is stored in a Flash ch

Pagina 80

HDD ... 3-2Power ...

Pagina 81 - 7-4.7 DMI Event Log

7-2SUPERSERVER 5014C-MF User's Manual7-2 Running Setup*Optimal default settings are in bold text unless otherwise noted.The BIOS setup options de

Pagina 82 - 7-4.8 Console Redirection

Chapter 7: BIOS7-3Date/TimeSet the system date and time. Key in the correct information in the "mm", "dd" and "yy" fi el

Pagina 83 - 7-5 Security

7-4SUPERSERVER 5014C-MF User's ManualIDE HDD Auto-DetectionThis option allows the user to determine the manner in which the AwardBIOS sets the se

Pagina 84 - 7-6 Boot

Chapter 7: BIOS7-57-4.1 Advanced BIOS FeaturesWhen the item of Advanced BIOS Features is highlighted, press the <Enter> key to activate the su

Pagina 85 - 7-7 Exit

7-6SUPERSERVER 5014C-MF User's ManualMPS Version ControlThis setting allows you to select the MPS version for your operating system. The option

Pagina 86

Chapter 7: BIOS7-7On-Chip Serial ATASelect "Disabled" to disable the SATA Controller. Select "Auto" to allow the BIOS to confi gure

Pagina 87 - Beeps Error Messages

7-8SUPERSERVER 5014C-MF User's Manual7-4.3 I/O Device Confi gurationOnboard Serial Port1/Onboard Serial Port2This setting allows the user to set

Pagina 88

Chapter 7: BIOS7-97-4.4 PnP/PCI Confi gurationChoose PCI/PnP Confi gurations from the Award BIOS main menu with the Left/Right arrow keys. You should

Pagina 89 - BIOS POST Codes

7-10SUPERSERVER 5014C-MF User's ManualMaximum Payload SizeThis setting allows the BIOS to set the maximum TLP Payload size for the PCI Express de

Pagina 90

Chapter 7: BIOS7-117-4.5 Hardware MonitorsThere are only three settings on this menu (below). The rest of this menu shows various temperatures and vo

Pagina 91 - Appendix B: BIOS POST Codes

viiiWake-On-Ring ... 5-16SATA LED ...

Pagina 92

7-12SUPERSERVER 5014C-MF User's Manual7-4.6 Processor & Clock OptionsThermal ManagementThis setting determines the method used by the BIOS

Pagina 93

Chapter 7: BIOS7-137-4.7 DMI Event LogDMI Event LogThis setting allows you to Enable or Disable the function of DMI Event Logging. The options are Di

Pagina 94

7-14SUPERSERVER 5014C-MF User's Manual7-4.8 Console RedirectionConsole RedirectionThis setting allows you to Enable or Disable the function of C

Pagina 95 - Software Installation

Chapter 7: BIOS7-15Set Supervisor PasswordWhen the item "Set Supervisor Password" is highlighted on the above screen, press the <Enter>

Pagina 96 - SATA Operating Modes

7-16SUPERSERVER 5014C-MF User's Manual7-6 BootChoose Boot from the Award BIOS main menu with the Left/Right arrow keys. You should see the follo

Pagina 97

Chapter 7: BIOS7-177-7 Exit Choose Exit from the Award BIOS main menu with the Left/Right arrow keys. You should see the following display: Save &am

Pagina 98 - Creating New A SATA RAID:

7-18SUPERSERVER 5014C-MF User's ManualNotes

Pagina 99

A-1Appendix A: BIOS POST Messages Appendix A BIOS POST MessagesDuring the Power-On Self-Test (POST), the BIOS will check for problems. If a

Pagina 100

A-2SUPERSERVER 5014C-MF User's ManualNotes

Pagina 101

Appendix B: BIOS POST CodesB-1Appendix B: BIOS POST CodesThis section lists the POST (Power On Self Testing) Codes for the Award BIOS.POST (hex)

Pagina 102 - Initializing Disk Drives

Table of Contentsix7-4.1 Advanced BIOS Features ... 7-57-4.2 Advanced Chipset Control

Pagina 103 - Creating Hot Spare Drives

B-2SUPERSERVER 5014C-MF User's ManualPOST (hex) Defi nition 12h Use walking 1's algorithm to check out interface in CMOS circuitry. A

Pagina 104

Appendix B: BIOS POST CodesB-3POST (hex) Defi nition 2Fh Reserved30h Reserved31h Reserved32h Reserved33h Reset keyboard except Winbond 977 seri

Pagina 105

B-4SUPERSERVER 5014C-MF User's ManualPOST (hex) Defi nition 52h Test all memory (clear all extended memory to 0)53h Reserved54h Reserved55

Pagina 106 - Installing Other Drivers

Appendix B: BIOS POST CodesB-5POST (hex) Defi nition 74h Reserved75h Detect and install all IDE devices: HDD, LS120, ZIP, CD-ROM, etc.76h Reser

Pagina 107 - Supero Doctor III

B-6SUPERSERVER 5014C-MF User's ManualPOST (hex) Defi nition 94h 1. Enable L2 cache2. Program boot up speed3. Chipset fi nal initialization4

Pagina 108

Appendix C: Software InstallationC-1 Appendix C Software Installation If you do not wish to confi gure SATA RAID, proceed directly to Section C-3. A

Pagina 109 - System Specifi cations

C-2SUPERSERVER 5014C-MF User's ManualConfi guring BIOS Settings (Native Mode)1. Press the Del key during system bootup to enter the BIOS Setup Uti

Pagina 110

Appendix C: Software InstallationC-3Using the LSI ICH6R SATA RAID Utility DriverNote: Please refer to the LSI User's Guide (included in the CD) t

Pagina 111

C-4SUPERSERVER 5014C-MF User's ManualCreating New A SATA RAID:1. From the Main Menu (shown on the previous page), select "Confi gure" an

Pagina 112

Appendix C: Software InstallationC-54. When the screen shown above appears, press the space bar on your keyboard to select the physical drives that y

Comentarios a estos manuales

Sin comentarios