Rev. 1.0bAOC-USAS-L4i AOC-USAS-L4iRUSER'S GUIDE1 314ACACACACACACACACACACACACACACACACACPCB EDGEPCB EDGEWWNBAR CODE1 3AFAEADACABAAYWVTRPNMLKJUHGFED
1-2 Add-on Card User's GuideNotes
2-1Safety Information and Technical Specifications1 314ACACACACACACACACACACACACACACACACACPCB EDGEPCB EDGEWWNBAR CODE1 3AFAEADACABAAYWVTRPNMLKJUHGFEDCBA
2-2 Add-on Card User's Guide2-2 Front Connector and Pin Definitions#3. Active LED ConnectorAllows the add-on card to display activity and
2-3Safety Information and Technical Specifications2-3 Front Jumper Locations and Pin DefinitionsJumper SettingsJumper Jumper Settings NoteSWR51-2: Enabl
2-4 Add-on Card User's GuideFront Pane LEDsLED STATE SPECIFICATIONLED1 Flashing SAS Port ActivityLED2 Flashing Heartbeat and FaultLNP0 ON Fau
2-5Safety Information and Technical SpecificationsRAID Minimum Drive RequirementsRAID Minimum Hard DrivesRAID 0 2RAID 1 2RAID 5* 3*RAID 10 4 (2 RAID 1
2-6 Add-on Card User's GuideNotes
3-1Safety Information and Technical SpecificationsChapter 3 Driver InstallationThe MegaRAID BIOS Configuration Utility (CU) is used to configure disk a
3-2 Add-on Card User's Guide3-2 Configuring Arrays and Logic Drives This section provides detailed instructions for configuring arrays and logic
3-3Safety Information and Technical SpecificationsNote: When you start the MegaRAID BIOS CU by pressing Ctrl-H the Configuration Manager Module of the B
ii Add-on Card User's GuideThe information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assum
3-4 Add-on Card User's GuideFigure 3-2: Logical Drive Configuration8. Highlight RAID and press Enter.The available RAID levels for the current
3-5Safety Information and Technical SpecificationsFollow these steps to configure a disk array using the New Configuration or View/Add Configuration optio
3-6 Add-on Card User's Guide9. Select a RAID level for the logical drive and press Enter.10. (Optional) Set the logical drive size by highligh
3-7Safety Information and Technical Specifications3. Select an unconfigured drive or Ready drive from the list, and press Enter.4. When the Physical
3-8 Add-on Card User's Guide5. After the initialization is complete, press Esc to return to previous menus.If you press Esc while initial
3-9Safety Information and Technical Specifications4. Select Yes at the prompt and press Enter.The CU displays a bar graph showing the initialization pr
3-10 Add-on Card User's Guide3. Use the arrow key to select Off or On for Disk WC (DWC) or Read Ahead.4. When you see the prompt Change DWC or
3-11Safety Information and Technical Specifications4. When rebuild is complete, the CU displays the message:Rebuilding of Drive X Completed Succes
3-12 Add-on Card User's Guide• CU menus such as Select Boot Drive, Select Adapter, and Logical Drive menus will completely or partially clo
3-13Safety Information and Technical Specifications4. Press F10.5. At the prompt, select Yes to start the Check Consistency process and pr
iiiSafety Information and Technical SpecificationsTable of ContentsIntroductionOverview ...
3-14 Add-on Card User's GuideViewing and Changing Adapter PropertiesTo view or change adapter properties, follow these steps:1. On the Managem
3-15Safety Information and Technical SpecificationsViewing and Changing Logical Drive PropertiesTo view or change logical drive properties, follow thes
3-16 Add-on Card User's Guide3-9 Configuring a Bootable Logical DriveThe default boot logical drive is LD 0. If you change the boot drive to an
4-1Safety Information and Technical SpecificationsChapter 4MegaRAID Storage Manager Software Overview and InstallationMegaRAID Storage Manager software
4-2 Add-on Card User's GuideYou can use the Configuration Wizard Auto Configuration mode to automatically create the best possible confi
4-3Safety Information and Technical Specifications4-3 InstallationThis section explains how to install (or reinstall) MegaRAID Storage Manager soft-war
4-4 Add-on Card User's Guide4. Enter your user name and organization name. In the bottom part of the screen, select an installation option:– I
4-5Safety Information and Technical SpecificationsFigure 4.2: Customer Information Screen7. Select one of the Setup options. The options are
4-6 Add-on Card User's GuideIf you select Client installation for a PC used to monitor servers, and if there are no available servers with a r
4-7Safety Information and Technical SpecificationsLinux Error MessagesOne or more of the following messages may appear while you are installing Mega-RA
iv Add-on Card User's Guide3-11 Clearing a Storage Configuration ... 3-16Chap
4-8 Add-on Card User's GuideNotes
5-1Safety Information and Technical SpecificationsChapter 5MegaRAID Storage Manager Window and MenusThis chapter explains how to start MegaRAID Storage
5-2 Add-on Card User's GuideFigure 5-1: Select Server WindowIf the circle in the server icon is yellow instead of green, it means that the ser
5-3Safety Information and Technical SpecificationsFigure 5-2: Select Server Window3. Select an access mode from the drop-down menu.– Select Full Access
5-4 Add-on Card User's Guide5-2 MegaRAID Storage Manager WindowThis section describes the MegaRAID Storage Manager window, which is s
5-5Safety Information and Technical SpecificationsPhysical/Logical View PanelThe left panel of the MegaRAID Storage Manager window displays e
5-6 Add-on Card User's GuideProperties/Operations/Graphical View PanelThe right panel of the MegaRAID Storage Manager window has either two or
5-7Safety Information and Technical SpecificationsMenu BarHere are brief descriptions of the main selections on the MegaRAID Storage Man-ager menu bar.
5-8 Add-on Card User's GuideLog MenuThe Log menu includes options for saving and clearing the message log. Help MenuOn the Help menu you
6-1Safety Information and Technical SpecificationsChapter 6ConfigurationYou use MegaRAID Storage Manager software to create and modify storage
vSafety Information and Technical Specifications6-8 Adding a Saved Storage Configuration ... 6
6-2 Add-on Card User's GuideFigure 6-1: First Screen Configuration WizardThe menu lists three configuration modes:• Auto Configuration automatica
6-3Safety Information and Technical SpecificationsThe following subsections explain how to use the Configuration Wizard to create storage con
6-4 Add-on Card User's GuideUsing Auto ConfigurationAuto Configuration is the quickest and simplest way to create a new storage configu-ration. W
6-5Safety Information and Technical Specifications2. Select an initialization option from the drop-down menu at the bottom of the window:–
6-6 Add-on Card User's GuideFigure 6-3: First Guided Conguration ScreenFollow these steps to create a new storage configuration in Guided Config
6-7Safety Information and Technical Specifications3. Select a maximum number of virtual disks to be created. The Configuration Wizard may no
6-8 Add-on Card User's GuideUsing Manual Configuration: RAID 0Follow these steps to create a RAID 0 storage configuration using the
6-9Safety Information and Technical SpecificationsFigure 6-6: Manual Configuration - Defining a Virtual DiskThe Arrays with Free Space menu lists the new
6-10 Add-on Card User's GuideUsing Manual Configuration: RAID 1Follow these steps to create a RAID 1 storage configuration using the
6-11Safety Information and Technical Specifications4. To remove a hotspare from an array, select it in the right panel and click Remove HotSpare.5. Cli
vi Add-on Card User's GuideNotes
6-12 Add-on Card User's GuideUsing Manual Configuration: RAID 5Follow these steps to create a RAID 5 storage configuration using the Manual Con-
6-13Safety Information and Technical SpecificationsUsing Manual Configuration: RAID 10Follow these steps to create a RAID 10 storage configurati
6-14 Add-on Card User's Guide10. Click Accept to accept the configuration of the new virtual disk.Note: Click the Reclaim button if you
6-15Safety Information and Technical Specifications6-3 Changing Adjustable Task RatesFollow these steps if you need to change the adjustable rates for
6-16 Add-on Card User's Guide6-4 Changing Virtual Disk PropertiesYou can change a virtual disk’s Read Policy, Write Policy, and other properti
6-17Safety Information and Technical Specifications6-6 Saving a Storage Configuration to DiskYou can save an existing controller configuration to
6-18 Add-on Card User's Guide6-8 Adding a Saved Storage ConfigurationWhen you replace a controller, or when you want to duplicate an
viiSafety Information and Technical SpecificationsIntroductionOverviewThis manual is written for system integrators, PC technicians and knowledgeable
viii Add-on Card User's Guide Contacting SuperMicroHeadquartersAddress: SuperMicro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel:
1-1Safety Information and Technical SpecificationsChapter 1 Safety GuidelinesTo avoid personal injury and property damage, carefully follow all the s
Comentarios a estos manuales